Full-scale sewerage system ST 510

Full-scale sewerage system

Type: ST 510
Name: Full-scale sewerage system
Categorie:

Description

The routing of sewers is particularly important in wastewater engineering. Pipe inclinations, pipe inlets and outlet, reducers and cross-sections must be considered when designing systems, taking into account interactions between the components. In particular, the pressure distribution in complex pipe systems places high demands on design engineers. Design errors lead to noise, empty drain traps and clogged pipes.

ST 510 allows a variety of experiments in the field of wastewater engineering and enables the visualisation of flow processes in sewers.

The experimental plant includes an extensive drainage pipe system based on common real-world elements. The pipes are transparent to allow visualisation of the flow processes. The cisterns are located in the top part of the experimental plant. These are opened or closed individually via solenoid valves. In addition, the bypass, ventilation pipe and pressure flushing are equipped with solenoid valves. The solenoid valves are triggered via a remote control. The system can be used to study the flow and pressure curve at different types of junctions, pipe offsets, cross-sectional changes and drain traps under different ventilation and evacuation conditions. The system contains a closed water circuit with collection tank and pump.

There are pressure measuring points located along the downcomer to measure the pressure conditions in the wastewater system. The measuring points are connected to a tube manometer via hose connections. The flow rate is determined via a rotameter.

Technical details

Specification
  • experimental plant for demonstration of wastewater technology
  • transparent glass pipes and tanks
  • 10 cisterns with remotely-operated solenoid valves
  • 1 toilet with cistern
  • 1 toilet with pressure flush
  • contains downcomer, collection pipe, ventilation pipe and bypasses
  • 6 tube manometers to indicate the pressure curve in the downcomer
  • measurement of flow rate via rotameter
  • Technical data

    Pump

    • power consumption: 550W
    • max. flow rate: 70L/min
    • max. head: 42m

    Collection tank

    • volume: approx. 300L

    Transparent cisterns

    • 4x 20L
    • 6x 10L

    Cistern

    • 1x 9L

    Flush for toilet: max. 9L


    Measuring ranges
    • flow rate: 0,4…4L/h
    • pressure: 6x 1500mmWC

    230V, 50Hz, 1 phase
    230V, 60Hz, 1 phase
    120V, 60Hz, 1 phase
    UL/CSA optional

    Dimensions and weight

    LxWxH: 5700x800x3900mm
    Weight: approx. 1100kg

    Required for operation

    Compressed air connection: 6…10bar

    Documentatie

    Foto's