Heat exchangers in the refrigeration circuit ET 431

Heat exchangers in the refrigeration circuit

Type: ET 431
Name: Heat exchangers in the refrigeration circuit
Categorie:

Description

Heat exchangers are an elementary part of refrigeration systems. During cooling they are used to absorb the energy of the refrigerant by evaporation. During heating they discharge the energy set free during the condensation of the refrigerant. They are also used for internal energy transfer during superheating or supercooling of the refrigerant.

Dependent on the media, a difference is made between air / refrigerant, water / refrigerant and refrigerant / refrigerant heat exchangers. Dependent on the constructive design, a difference is also made between coaxial, finned tube, plate or shell and tube heat exchangers.

The refrigeration circuit of the trainer ET 431 includes as evaporator an air cooling finned tube heat exchanger and a water-heated plate heat exchanger, as superheater a tubular heat exchanger, and as condenser a water-cooled coaxial coil heat exchanger. These heat exchangers are the ones used most commonly in refrigeration and fulfil different functions dependent on the system type. A finned tube heat exchanger can e.g. also be used as a condenser.

The components are arranged clearly at the front. By measuring the mass flow rates and the inlet and outlet temperatures the transferred energy fluxes can be determined.

Technical details

Specification
  • refrigeration system with 4 different heat exchangers: coaxial coil heat exchanger, finned tube heat exchanger, tubular heat exchanger, plate heat exchanger
  • combinations of different media: water / refrigerant, refrigerant / refrigerant, air / refrigerant
  • water circuit with tank and pump to cool the condenser and heat the evaporator
  • superheater can be disabled via bypass
  • flow meter and thermometer in the water circuit to determine the exchanged energy fluxes
  • thermometers at all relevant points of the system
  • refrigerant R134a, CFC-free
  • Technical data

    Compressor

    • refrigeration capacity: 625W at -5/32°C
    • power consumption: 358W at -10/32°C

    Receiver

    • 1,3L

    Measuring ranges
    • pressure: -1…9bar / -1…24bar
    • temperature: 12x -5…105°C, 1x 0…60°C
    • flow rate: 1x 2…27L/h (R134a), 2x 20…250L/h

    230V, 50Hz, 1 phase
    230V, 60Hz, 1 phase

    Dimensions and weight

    LxWxH: 1900x800x1900mm
    Weight: approx. 255kg

    Required for operation

    water connection, drain

    Documentatie

    Foto's